Skip to main content

Ferrite Transformer Turns Calculation for High Frequency SMPS Inverter



On different forums, I often find people asking for help in calculating the required turns for a ferrite transformer they are going to use in high-frequency/SMPS inverters. In a high-frequency/SMPS inverter, the ferrite transformer is used in the step-up/boost stage where the low voltage DC from the battery is stepped up to high voltage DC. In this situation, there are really only two choices when selecting topology – push-pull and full-bridge. For transformer design, the difference between a push-pull and a full-bridge transformer for same voltage and power will be that the push-pull transformer will require a center tap, meaning it will require twice the number of primary turns as the full-bridge transformer.

Calculation of required turns is actually quite simple and I’ll explain this here.

For explanation, I’ll use an example and go through the calculation process.

Let’s say the ferrite transformer will be used in a 250W inverter. The selected topology is push-pull. The power source is a 12V battery. Output voltage of the DC-DC converter stage will be 310V. Switching frequency is 50kHz. The selected core is ETD39. Remember that the output of the transformer will be high frequency AC (50kHz square wave in this case). When I refer to an output of high voltage DC (eg 310VDC mentioned above), this is the DC output obtained after rectification (using ultrafast recovery diodes configured as bridge rectifier) and filtration (using LC filter).

During operation, the battery voltage does not stay fixed at 12V. With high loads, the voltage will be less than 12V. With low loads and near-fully charged battery, the voltage may be higher than 13V. So, it must be kept in mind that the input voltage is not constant, but is variable. In inverters, the battery low-cut is usually set at 10.5V. So, we’ll take this as our lowest possible input voltage.

Vinmin = 10.5V

The formula for calculating the number of required primary turns is:

 
For our push-pull transformer, this will be one-half the required number of turns.
Npri means number of primary turns; Nsecmeans number of secondary turns; Naux means number of auxiliary turns and so on. But just N (with no subscript) refers to turns ratio.

For calculating the required number of primary turns using the formula, the parameters or variables that need to be considered are:

  • Vin(nom) – Nominal Input Voltage. We’ll take this as 12V. So, Vin(nom) = 12.
  • f – The operating switching frequency in Hertz. Since our switching frequency is 50kHz, f = 50000.
  • Bmax – Maximum flux density in Gauss. If you’re used to using Tesla or milliTesla (T or mT) for flux density, just remember that 1T = 104 Gauss. Bmax really depends on the design and the transformer cores being used. In my designs, I usually take Bmaxto be in the range 1300G to 2000G. This will be acceptable for most transformer cores. In this example, let’s start with 1500G. So Bmax = 1500. Remember that too high a Bmax will cause the transformer to saturate. Too low a Bmax will be under utilizing the core.
  • Ac – Effective Cross-Sectional Area in cm2. You will get this information from the datasheets of the ferrite cores. Ac is also sometimes referred to as Ae. For ETD39, the effective cross-sectional area given in the datasheet/specification sheet (I’m referring to TDK E141. You can download it from here: www.tdk.co.jp/tefe02/e141.pdf  ), the effective cross-sectional area (in the specification sheet, it’s referred to as Aebut as I’ve said, it’s the same thing as Ac) is given as 125mm2. That is equal to 1.25cm2. So, Ac = 1.25 for ETD39.
 
So now, we’ve obtained the values of all required parameters for calculation Npri – the number of required primary turns.

Vin(nom) = 12                                        f = 50000                              Bmax= 1500                          Ac = 1.25

Plugging these values into the formula:



                        Npri= 3.2


We won’t be using fractional windings, so we’ll round off Nprito the nearest whole number, in this case, rounded down to 3 turns. Now, before we finalize this and select Npri = 3, we better make sure that Bmaxis still within acceptable bounds. As we’ve decreased the number of turns from the calculated figure (down to 3.0 from 3.2), Bmax will increase. We now need to figure out just how much Bmax has increased and if that is still an acceptable value.

Vin(nom) = 12                 f = 50000                     Npri= 3                         Ac= 1.25




 
                                                                   Bmax= 1600


The new value of Bmax is well within acceptable bounds and so we can proceed with Npri = 3.

So, we now know that for the primary, our transformer will require 3 turns + 3 turns.

In any design, if you need to adjust the values, you can easily do so. But always remember to check that Bmax is acceptable.

  • For example, if for construction difficulties, winding 3 turns + 3 turns becomes difficult, you may use 2 turns + 2 turns or 4 turns + 4 turns. Increasing number of turns won’t hurt – you’ll just be under utilizing the core. However, decreasing number of turns increases Bmax, so just recheck to make sure Bmax is okay. The range I’ve stated for Bmax(1300G to 2000G) is just an estimate. It will work for most cores. However, with many cores, you can go higher to decrease the number of turns. Going lower will just be under utilizing the core, but may sometimes be required if number of turns is too low. 
 
  • I’ve started off with a set Bmax and gone on to calculate Npri from there. You can also assign a value of Npriand then check if Bmax is okay. If not, you can then increase or decrease Npri as required and then check if Bmax is okay, and repeat this process until you get a satisfactory result. For example, you may have set Npri = 2 and calculated Bmax and decided that this was too high. So, you set Npri = 3 and calculated Bmax and decided it was okay. Or you may have started with Npri = 4 and calculated Bmax and decided that it was too low. So, you set Npri = 3 and calculated Bmax and decided it was okay.


Now it’s time to move on to the secondary. The output of our DC-DC converter is 310V. So, the transformer output must be 310V at all input voltages, from all the way up from 13.5V to all the way down to 10.5V. Naturally, feedback will be implemented to keep the output voltage fixed even with line and load variations – changes due to battery voltage change and also due to load change. So, some headroom must be left for feedback to work. So, we’ll design the transformer with secondary rated at 330V. Feedback will just adjust the voltage required by changing the duty cycle of the PWM control signals. Besides feedback, the headroom also compensates for some of the losses in the converter and thus compensates for the voltage drops at different stages – for example, in the MOSFETs, in the transformer itself, in the output rectifiers, output inductor, etc.

This means that the output must be capable of supplying 330V with input voltage equal to 10.5V and also input voltage equal to 13.5V. For the PWM controller, we’ll take maximum duty cycle to be 98%. The gap allows for dead-time.

At minimum input voltage (when Vin = Vinmin), duty cycle will be maximum. Thus duty cycle will be 98% when Vin = 10.5 = Vinmin. At maximum duty cycle = 98%, voltage to transformer = 0.98 * 10.5V = 10.29V.

So, voltage ratio (secondary : primary) = 330V : 10.29V = 32.1

Since voltage ratio (secondary : primary) = 32.1, turns ratio (secondary : primary) must also be 32.1 as turns ratio (secondary : primary) = voltage ratio (secondary : primary). Turns ratio is designated by N. So, in our case, N = 32.1 (I’ve taken N as the ratio secondary : primary).

Npri = 3

Nsec = N * Npri = 32.1 * 3 = 96.3

Round off to the nearest whole number. Nsec = 96.

Thus 96 turns are required for the secondary. With proper implementation of feedback, a constant 310VDC output will be obtained throughout the entire input voltage range of 10.5V to 13.5V.

Here, one thing to note is that even though I took 98% as the maximum duty cycle, maximum duty cycle in practice will be smaller since our transformer was calculated to provide 330V output. In the circuit, the output will be 310V, so the duty cycle will be even lower. However, the advantage here is that you can be certain that the output will not drop below 330V even with heavy loads since a large enough headroom is provided for feedback to kick in and maintain the output voltage even at high loads.

If any auxiliary windings are required, the required turns can be easily calculated. Let me show with an example. Let’s say we need an auxiliary winding to provide 19V. I know that the output 310V will be regulated, whatever the input voltage may be, within the range initially specified (Vinmin to Vinmax – 10.5V to 13.5V). So, the turns ratio for the auxiliary winding can be calculated with respect to the secondary winding. Let’s call this turns ratio (secondary : auxiliary) NA.

NA = Nsec / Naux = Vsec/ (Vaux + Vd). Vd is the output diode forward drop. Let’s assume that in our application, a schottky rectifier with a Vd= 0.5V is used.

So, NA = 310V / 19.5V =15.9

Nsec / Naux = NA

Naux = Nsec / NA = 96 / 15.9= 5.96

Let’s round off Naux to 6 and see what the output voltage is.

Vsec / (Vaux + Vd) = NA= Nsec / Naux = 96 / 6 =16.0

(Vaux + Vd) = Vsec / NA= 310V / 16.0 = 19.375V

Vaux = 19.375V – 0.5V = 18.875V (rounded off)

I would say that’s great for an auxiliary supply. If in your calculations you come to a voltage that is too far off the required target voltage and thus greater accuracy is required, take Vaux as something higher and use a voltage regulator.

For example, if in our previous example, instead of18.875V we had gotten 19.8V but needed more accuracy, we could've used 24V or thereabouts and used a voltage regulator to give 19V output.

So, there we have it. Our transformer has 3 turns + 3 turns for primary, 96 turns for secondary and 6 turns for auxiliary.

Here’s our transformer:

Calculating required number of turns for a transformer is actually a simple task and I hope that I could help you understand how to do this. I hope this tutorial helps you in your ferrite transformer designs. Do let me know your comments and feedback.



Comments

Popular posts from this blog

Build a 3000W Stereo Power Amplifier Circuit Diagram

How to Build a 3000W Stereo Power Amplifier Circuit Diagram? Lets start first we define 3000wstereo power amplifier circuit diagram this circuit has a power output of up to 1500W RMS power amplifier circuit is often used to power sound systems spelunker for outdor. In the final image can be seen a series of power amplifiers using 10 sets of power transistors for the ending. This power amplifier circuit using a transistor amplifier from the front, signal splitter, driver and power amplifier. Current consumption required is quite large power amplifier that is 15-20 A 1500W power amplifier circuits for this. Supply voltage needed by the power of this amplifier is the optimal working order symmetrical 130VDC (130VDC-130VDC ground). 1500W amplifier circuit below is a picture series of mono, stereo if you want to make it necessary to make two copies of the circuit. For more details can be viewed directly image the following 1500W power amplifier circuit. The series of High Power Amplifier 15

Solid State Switch For Dc Operated Gadgets

This solid state DC switch can be assembled using just three transistors and some passive components. It can be used to switch on one gadget while switching off the second gadget with momentary operation of switch. To reverse the operation, you just have to momentarily depress another switch.  The circuit operates over 6V-15V DC supply voltage. It uses positive feedback from transistor T2 to transistor T1 to keep this transistor pair in latched state (on/ off), while the state of the third transistor stage is the complement of transistor T2’s conduction state.  Initially when switch S3 is closed, both transistors T1 and T2 are off, as no forward bias is available to these, while the base of transistor T3 is effectively grounded via resistors R8 and R6 (shunted by the load of the first gadget). As a result, transistor T3 is forward biased and gadget 2 gets the supply. This is indicated by glowing of LED2.  Circuit diagram : Solid-State Switch For Dc-Operated Gadgets Circuit Diagram Whe

Amplifier Circuit 2 X 10 watt with IC AN7145

This is Stereo Amplifier On this schematic amplifier circuit  use the ic AN7145L , but can use the following IC : AN7145M AN7145H AN7146M AN7146H You can use of all ic above. anthis circuit need suply voltage with dual voltage . Minimum voltage 6 Volt and maximum voltage 20 volt . Voltage just (-) and (+), but (-) can also ground. Maximum power output 2 X 20 watt with minimum impedance 4 ohm. Click image to view enlarge. You can operate this circuit with  plugging input to , PC or other media can give signal audio.