Garage Door Closing Circuit Just using Relays

Because I’m old school, I wanted to build a Garage Door Closing circuit without relying on integrated configurations (555 timer etc) to keep it simplistic. The circuit closes the garage door after two minutes with C3 and four minutes with the addition of C2. The timer relay is surprisingly accurate (+/- five seconds). Another feature is to ensure that the garage door actually did close, such as if it’s stopped mid-operation by the user. Description: S3 (magnetic N.C.) is located at the garage door and activates the circuit when the garage door opens. RL1 is the reset timer. It’s maintained in the “on” position for two minutes by C3 while the trigger capacitor, C4, is charged. RL2 is the conduit, directing C4 to either RL3 or R1 to ground when off. Purpose of R1 is to prevent arching across contacts and a fast discharge. RL3’s contacts are connected to the Garage Door’s Momentary Switch and is sustained “on”  for a half second by C5. When C3 discharges to the cutoff voltage of RL1, ...

Fan Controller Using Just Two Component Circuit Diagram

Fan Controller Using Just Two Component Circuit diagram. The Maxim MAX 6665 (www.maxim-ic.com) provides a complete temperature-dependent fan controller. It can switch fans operating at voltages of up to 24 V and currents of up to 250 mA. The IC is available from the manufacturer in versions with preset threshold temperatures between +40 °C (MAX6665 ASA40) and +70 °C (MAX6665 ASA 70). The device’s hysteresis can be set by the user via the HYST input, which can be connected to +3.3 V, connected to ground, or left open. The following table shows the hysteresis values available: HYST = Hysteresis open = 1 °C ground = 4 °C +3.3V = 8 °C Fan Controller Using Just Two Component Circuit diagram: Fan Controller Circuit Diagram The other pins of the SO8 package are the FORCEON input and the status outputs WARN, OT and FANON. The test input FORCEON allows the fan to be run even below the threshold temperature. The open-drain output WARN goes low when the temperature rises more than 15 °C above th...

Fan Controller Using Just Two Component

Fan Controller Using Just Two Component Circuit diagram. The Maxim MAX 6665 (www.maxim-ic.com) provides a complete temperature-dependent fan controller. It can switch fans operating at voltages of up to 24 V and currents of up to 250 mA. The IC is available from the manufacturer in versions with preset threshold temperatures between +40 °C (MAX6665 ASA40) and +70 °C (MAX6665 ASA 70). The device’s hysteresis can be set by the user via the HYST input, which can be connected to +3.3 V, connected to ground, or left open. The following table shows the hysteresis values available: HYST = Hysteresis open = 1 °C ground = 4 °C +3.3V = 8 °C Fan Controller Using Just Two Component Circuit diagram: Fan Controller Circuit Diagram The other pins of the SO8 package are the FORCEON input and the status outputs WARN, OT and FANON. The test input FORCEON allows the fan to be run even below the threshold temperature. The open-drain output WARN goes low when the temperature rises more than 15 °C above th...

Fan Controller Using Just Two Component

The Maxim MAX 6665 (www.maxim-ic.com) provides a complete temperature-dependent fan controller. It can switch fans operating at voltages of up to 24 V and currents of up to 250 mA. The IC is available from the manufacturer in versions with preset threshold temperatures between +40 °C (MAX6665 ASA40) and +70 °C (MAX6665 ASA 70). The device’s hysteresis can be set by the user via the HYST input, which can be connected to +3.3 V, connected to ground, or left open. The following table shows the hysteresis values available: HYST = Hysteresis open = 1 °C ground = 4 °C +3.3V = 8 °C Fan Controller Using Just Two Component Circuit diagram: Fan Controller Circuit Diagram The other pins of the SO8 package are the FORCEON input and the status outputs WARN, OT and FANON. The test input FORCEON allows the fan to be run even below the threshold temperature. The open-drain output WARN goes low when the temperature rises more than 15 °C above the threshold temperature, while the open-drain output OT i...

Fan Controller Using Just Two Components

The Maxim MAX 6665 (www.maxim-ic.com) provides a complete temperature-dependent fan controller. It can switch fans operating at voltages of up to 24 V and currents of up to 250 mA. The IC is available from the manufacturer in versions with preset threshold temperatures between +40 °C (MAX6665 ASA40) and +70 °C (MAX6665 ASA 70). The device’s hysteresis can be set by the user via the HYST input, which can be connected to +3.3 V, connected to ground, or left open. The following table shows the hysteresis values available: HYST = Hysteresis open = 1 °C ground = 4 °C +3.3V = 8 °C   Fan Controller Circuit Diagram The other pins of the SO8 package are the FORCEON input and the status outputs WARN, OT and FANON. The test input FORCEON allows the fan to be run even below the threshold temperature. The open-drain output WARN goes low when the temperature rises more than 15 °C above the threshold temperature, while the open-drain output OT indicates when the temperature is more than 30 °C abo...